4. SCON-CA


241

CompoNet

(27) Torque level (TRQS) PLC input signal

This signal is available only in the pressing operation.
When the motor current reaches the load threshold during the pressing operation (moving up to the
positioning band), this signal is turned “ON”.
Because the current level is monitored, when the current level is changed, this signal is turned “ON”.
The velocity available for the pressing varies depends on the motor and leads, it is required to adjust the
parameters.
















x Set the pressing velocity using the parameter No. 34 “Pressing Speed”.
When the machine is delivered, it has been individually set depending on the actuator characteristics.
Set an appropriate speed considering the work part material and shape.
x Set the parameter No. 50 “Load Output Judgment Time Period”.

x Set the threshold using the PLC's Load Current Threshold Register.

x Set the positioning band using the PLC's Positioning Band Register.
Set it a bit longer from the backmost position considering the mechanical dispersion of the work part.
Refer to the Operation Manual for the controller for more information.












Caution: The actuator continues to push the work with the pressing current at the stop time decided

with the current limit value.
It is not the stop condition, so take the greatest care to deal with it.

Velocity

Position where the actuator is pushed against the work and
the pressing completion is judged so the positioning completion
signal is turned "ON"

Positioning Width (Max. Pressing Level)

Target Position

Travel

Range where the TRQS signal is output.