10-5

IM DR231-01E

Basic Settings (SET-UP)

10

10.2 Setting Recording Format

Selection of Printing When Chart Speed Is Changed (SPEED CHANGE PR)

When the chart speed is changed in dot-recording, select whether to print with the changed chart
speed or not.
• OFF: does not print.
• ON: prints.
• The default setting is ON.

Selection of Printing Record-Start/Stop Time (ON/OFF MARK PR)

In trend recording, select whether the record-start/stop time is printed or not.
• OFF: not printed.
• ON: printed.
• The default setting is ON.

Selection of Number of Columns for Digital Printing (DIGITAL PR CLMN)

Select to print measured values for the number of channels in a horizontal line.
DR130:
• Select either 1 or 2 columns.
• The default setting is 1.
• If TAG is defined using 8 or more characters, the recorder prints for the option "1 column."
DR231/241:
• Select 1, 2, 3, or 4.
• The default setting is 1.
• If TAG has been selected in selecting the channel number/TAG, choice is 1, 2, or 3 when the

TAG name consists of 8 characters or more.

• If TAG uses 16 characters, the TAG entry is limited to two columns.

Selection of Channel Number Printing Pitch (CHANNEL PITCH)

In trend recording, select how many millimeters are taken as the channel number printing interval.
When TAG has been selected in channel number/TAG selection, the TAG corresponding to the
channel number is printed.
• OFF: not printed.
• 5.0 mm: printed every 5.0 mm.
• 12.5 mm: printed every 12.5 mm.
• The default setting is 5.0 mm.

Selection of Title Printing Pitch (TITLE PITCH)

In trend recording, select how many millimeters are taken as the title printing interval. For setting
a title, see Section 6.7, “Entering Messages, Headers and Title” (page 6-15).
• OFF: not printed.
• 600 mm: printed every 600 mm.
• 1500 mm: printed every 1500 mm.
• The default setting is 1500 mm.

Selection of Scale Check Mark Printing (SCALE TIC PR)

In trend recording, select whether a tic mark indicating the scale mark positions is printed or not.
For setting the scale mark printing, see Section 6.6, “Setting Scale Printout, List Printout and List
Format” (page 6-13).
• OFF: not printed
• ON: printed
• The default setting is OFF.

Selection of Horizontal or Vertical Printing (LOG FORMAT)

In logging mode, select either horizontal or vertical printing of the channel number/TAG. For
examples of printing, see Section 2.3, “Recording Functions” (page 2-8).
• HORIZON: printed horizontally.
• VERTICAL: printed vertically
• The default setting is HORIZON.