Yokogawa DR240 User Manual

Page 229

Advertising
background image

14-2

IM DR231-01E

14.1 Specifications of DR130/DR231/DR241 (Style S3)

Common mode noise voltage

250VAC rms (50/60Hz)

Common mode rejection ratio

120dB or greater (50/60Hz

±0.1%, 500Ω unbalanced, between the negative measurement terminal

and ground)

Maximum noise between channels

150VAC rms (50/60Hz)

Measurement range, accuracy and resolution

As described below, under the following operating conditions:

Ambient temperature: 23

±2°C; ambient humidiy: 55 ±10% RH; power supply voltage: 90 to

250 VAC (AC power supply) or 10 to 32 VDC (DC power supply)/90 to 132/80 to 250 VAC
(when /P6 option is specified); power supply frequency: 50/60Hz within

±1%; warm-up time

30 minutes or more; vibrations and others not affecting instrument operation.
However, RTD input is not available with the DCV/TC/DI input module

Input

Measurement (digital display)

DC Voltage

TC
(Note that Accuracy
of reference junction
compensation is not
considered).

RTD

High resolution RTD

Contact

20mV
60mV
200mV
2V
6V
20V
50V
R

S
B
K

E
J
T
L
U
N
W
KPvsAu7Fe
Pt100(1mA)
Pt100(2mA)
JPt100(1mA)
JPt100(2mA)
Pt50(2mA)
Ni100(1mA)
SAMA
Ni100(1mA)DIN
Ni120(1mA)
J263*B
Cu10 GE
Cu10 L&N
Cu10 WEED
Cu10 BAILEY
Pt100(1mA)
Pt100(2mA)
JPt100(1mA)
JPt100(2mA)
Voltage input

Contact input

–20.000 to 20.000mV
–60.00 to 60.00mV
–200.00 to 200.00mV
–2.0000 to 2.0000V
–6.000 to 6.000V
–20.000 to 20.000V
–50.00 to 50.00V
0.0 to 1760.0

°C

0.0 to 1760.0

°C

0.0 to 1820.0

°C

–200.0 to 1370.0

°C

–200.0 to 800.0

°C

–200.0 to 1100.0

°C

–200.0 to 400.0

°C

–200.0 to 900.0

°C

–200.0 to 400.0

°C

0.0 to 1300.0

°C

0.0 to 2315.0

°C

0.0 to 300.0K
–200.0 to 600.0

°C

–200.0 to 250.0

°C

–200.0 to 550.0

°C

–200.0 to 250.0

°C

–200.0 to 550.0

°C

–200.0 to 250.0

°C

–60.0 to 180.0

°C

–70.0 to 200.0

°C

0.0 to 300.0K
–200.0 to 300.0

°C

–140.00 to 150.00

°C

–70.00 to 70.00

°C

–140.00 to 150.00

°C

–70.00 to 70.00

°C

OFF for a voltage of less
than 2.4V.
ON for a voltage of 2.4V
or more.(TTL)
ON/OFF of contact

Type

Measurement accuracy

Maximum

resolution

±(0.05% of rdg + 5digits)

±(0.05% of rdg + 2digits)

±(0.05% of rdg + 2digits)

±(0.05% of rdg + 2digits)

±(0.05% of rdg + 2digits)

±(0.05% of rdg + 2digits)

±(0.05% of rdg + 2digits)

±(0.05% of rdg + 1°C)
However,R,S:0 to 100

°C,±3.7°C

100 to 300

°C,±1.5°C

B:400 to 600

°C,±2°C accuracy

less than 400

°C is not specified.

±(0.05% of rdg +0.7°C)
However,K attains an accuracy of
±(0.05% of rdg. +1°C) within the
range between –200 to –100

°C.

±(0.05% of rdg +0.5°C)
However,J and L attain an accuracy of
±(0.05% of rdg. +0.7°C) within the
range between –200 to –100

°C.

±(0.05% of rdg. +0.7°C)

±(0.05% of rdg. +1°C)

±(0.05% of rdg. +0.7K)

±(0.05% of rdg. +0.3°C)

±(0.05% of rdg. +0.3°C)

±(0.05% of rdg. +0.3°C)

±(0.05% of rdg. +0.3°C)

±(0.05% of rdg. +0.3K)

±(0.2% of rdg. +0.7°C)

±(0.05% of rdg. +0.3°C)

±(0.05% of rdg. +0.3°C)

±(0.05% of rdg. +0.3°C)

±(0.05% of rdg. +0.3°C)
OFF for a voltage of less than 2.4V.

ON for a voltage of 2.4V or more.
(TTL)
ON/OFF of contact

Measurement range

1

µV

10

µV

10

µV

100

µV

1mV
1mV
10mV

0.1

°C

0.1K

0.1

°C

0.1K

0.1

°C

0.01

°C

*

1

*

1

*

1

*

1

*

1

*

1

*

1

*

2

*

2

*

3

*

4

*

5

*

5

*

5

*

5

*

5

*

6

*

6

*

7

*

8

*

8

*

8

*

8

*

5

*

5

*

5

*

5

*1 : R,S,B,K,E,J,T:ANSI,IEC 584,DIN IEC 584,JIS C 1602-1981
*2 : L:Fe-CuNi,DIN43710,U:Cu-CuNi,DIN 43710
*3 : N:Nicrosil-Nisil,IEC 584,DIN IEC 584
*4 : W:W·5%RE-W·26%Re (Hoskins Mfg Co)
*5 : Pt50:JIS C 1604-1981,JIS C 1606-1986
Pt100:JIS C 1604-1989,JIS C 1606-1989,IEC 751,DIN IEC 751
JPt100:JIS C 1604-1981,JIS C 1606-1989

*6 : SAMA/DIN
*7 : McGRAW EDISON COMPANY
*8 : ranges to which accuracy applies:
Cu10 GE:–84.4 to 170.0

°C,

Cu10 L&N:–75.0 to 150.0

°C,

Cu10 WEED:–200.0 to 250.0

°C,

Cu10 BAILEY:–200.0 to 250.0

°C

Advertising