13-3

IM DR231-01E

Trouble-shooting

and Maintenance

13

DR241

1. Turn off the power switch.
2. Disconnect the power connections.
3. Open the front and display doors to gain access to the fuse holder. Use a standard screwdriver

to turn the fuse-holder screw counterclockwise. Then remove the fuse holder.

4. Remove the blown fuse from the holder.
5. Insert a new fuse into the holder and then install the holder in place.

DR130/DR231/DR241 (in case of DC power supply)

1. Turn off the power switch.
2. Disconnect the power connections.
3. Use a standard screwdriver to turn the fuse-holder screw counterclockwise, located next to the

DC power terminals. Then remove the fuse holder.

4. Remove the blown fuse from the holder.
5. Insert a new fuse into the holder and then install the holder in place.

DR130

DR231

Note

The fuse is located in the case at the rear side of the main unit where the input/output module is connected.
This fuse may not be replaced by the customer. Fuse rating is a 250V2A time-lag fuse with IEC/VDE

certification for an AC power supply. It is a 250V6.3A time-lag fuse with UL/CSA certification for a DC

power supply.