Yokogawa DR240 User Manual

Page 234

Advertising
background image

14-7

IM DR231-01E

Specifications

14

14.1 Specifications of DR130/DR231/DR241 (Style S3)

Recording colors

Analog trend mode

Trend recording: purple, red, green, blue, brown, black, navy blue, yellowish green,
red-purple, orange (can be specified for each channel)
Digital printout: black
Alarm printout: red (however, alarm release mark: blue)

Logging mode

purple

Recording accuracy

DR130
Trend recording:

±(0.2% of recording span + measurement accuracy)

DR231/DR241
Trend recording:

±(0.1% of recording span + measurement accuracy)

Max. recording resolution

Trend recording:

±0.1mm

Recording interval

Recording interval for analog trend recording:

FIX:

Min2s, and same as measurement interval

AUTO: Min 2s, and Linked to measurement interval and chart speed

Digital printout interval for analog trend recording:

MULTIPLE:

Specify for each channel from 6 kinds of intervals

SINGLE:

Determined automatically from the chart speed and the number of channels
used to print digital values.

Digital value printing interval in the logging mode:

MULTIPLE:

Specify for each channel from 6 kinds of intervals

SINGLE:

Common to all points

Recording interval change: 2 kinds; changes by event/action function

Recording modes

Analog trend mode and logging mode

Chart paper feed

chart speed:

1 to 1500 mm/hour

chart speed change:

2 kinds; changes by event/action function

chart feed method:

by pulse motor

chart feed accuracy:

±0.1% of length (when recording is performed continuously for at least
1000mm; does not include elongation or shrinkage of paper)

Recording start/stop

Usually starting and stopping of recording is done by means of key operation. However, this can
also be done by the event/action function.
Normal recording
Trend recording on alarm occurrence: trigger/level
Group trend recording

Auxiliary printing functions

During analog trend recording and logging, setting information and comments will be printed.
Chart speed (mm/hour)

× trend recording interval must not exceed 3000.

Printout items:

Engineering unit, channel number/TAG, alarm, scale, title, message

Event/Action function

Recording can be started, or the chart speed changed by alarm output status/remote control signal/
chart end signal/timer or key operation.

Relation between the chart speed and recording interval (analog trend mode)

however, chart speed (mm/hour)

× trend recording interval must not exceed 3000.

Channel No./

TAG

Alarm/scale/

message

Digital print out

Record disabled

Record enabled

Record enabled

Record enabled

1 to 9mm/h

10 to 1500mm/h

Chart speed

Record enabled

Record enabled

Advertising