2 replacing the fuse, 2 replacing the fuse -2, Warning – Yokogawa DR240 User Manual

Page 217

Advertising
background image

13-2

IM DR231-01E

13.2 Replacing the Fuse

WARNING

• The fuse must be of the specified rating (current, voltage, type) to

prevent a fire hazard.

• When replacing the fuse, be sure to turn off the AC power switch and

check that the source of the DC power supply is turned OFF also.
Next, remove the AC power cord, power supply wires, and DC power
supply connector. Then, replace the fuse.

• Never short-circuit the fuse holder.

Fuse Rating

The fuse must have the following specifications:

For AC power supply
Maximum rated voltage: 250 V

Maximum rated current: 2.5 A

Type: time-lag

Standard: IEC/VDE certified

Part number: A1350EF

For DC power supply
Maximum rated voltage: 250V

Maximum rated current: 6.3A

Type: time-lag

Standard: IEC/VDE certified

Part number: A1354EF

Replacement procedure

To replace the fuse, proceed as follows:

DR130/DR231 (in case of AC power supply)

1. Turn off the power switch. Turn off the AC power switch also on the rear panel of the DC

power supply model.

2. Unplug the AC power cord from the power outlet.
3. Remove the fuse holder at the side of the AC power connector on the rear panel.
4. Remove the blown fuse from the holder.
5. Insert a new fuse into the holder and then install the holder in place.

DR130

DR130 DC power

DR231

DR231 DC power

model

model