P506 automatic error acknowledgement, P507 ppo-type, P508 profibus address – NORD Drivesystems BU0500 User Manual

Page 114

Advertising
background image

SK 500E – Users Manual for Frequency Inverters

114

BU 0500 GB-1013

P506

Automatic error
acknowledgement

(Automatic error acknowledgement)

S

0 ... 7

{ 0 }

In addition to the manual error acknowledgement, an automatic one can also be selected.

0 =

No automatic error acknowledgement.

1 ... 5 = Number of permissible automatic error acknowledgements within one mains-on

cycle. After mains off and switch on again, the full amount is again available.

6 =

Always: an error message will always be acknowledged automatically if the cause
of the error is no longer present.

7 =

Via Deactivate enable: acknowledgement is only possible using the OK / ENTER
key or by mains switch-off. No acknowledgement is implemented by removing the
enable!

NOTE: If (P428) is parameterised to "ON", parameter (P506) "Automatic error acknowledgement"
must not be parameterised to setting 6 "Always" as otherwise the device or system is endangered
due to the possibility of continuous restarting in the case of an active error (e.g. short-circuit to
earth / short circuit).

Pos : 266 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P500-P599/ Paramet er P507 – PPO-T yp @ 0\ mod_1328091974415_388.doc x @ 11042 @ @ 1

P507

PPO-Type

(PPO-Type)

1 ... 4

{ 1 }

This parameter can only be used with the technology unit Profibus, DeviceNet or InterBus.

See also the relevant section of the corresponding supplementary BUS manual.

Pos : 267 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P500-P599/ Paramet er P508 – Profibus-Adresse @ 0\ mod_1328092017167_388. doc x @ 11065 @ @ 1

P508

Profibus address

(Profibus address)

1 ... 126

{ 1 }

Profibus address, only with the technology unit Profibus

See also the additional description for the Profibus control BU 0020

Pos : 268 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P500-P599/ Paramet er P509 – Q uell e Steuerwort @ 0\ mod_1328092104264_388. doc x @ 11088 @ @ 1