5 Parameters

BU 0500 GB-1013

131

P701

[-01]

...

[-05]

Last fault

(Last fault 1...5)

0.0 ... 25.4

This parameter stores the last 5 faults.

The SimpleBox / ControlBox must be used to select the corresponding memory location 1...5-
(Array parameter), and confirmed using the OK / ENTER key to read the stored error code.

Pos : 328 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P700-P799/ Paramet er P702 – Frequenz letzt e St örung 1... 5 @ 0\ mod_1328170589463_388. doc x @ 12364 @ @ 1

P702

[-01]

...

[-05]

Last frequency error

(Last frequency error 1...5)

S

-400.0 ... 400.0 Hz

This parameter stores the output frequency that was being delivered at the time the fault occurred.
The values of the last 5 errors are stored.

The SimpleBox / ControlBox must be used to select the corresponding memory location 1...5-
(Array parameter), and confirmed using the OK- / ENTER key to read the stored error code.

Pos : 329 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P700-P799/ Paramet er P703 – Str om letzt e St örung 1... 5 @ 0\ mod_1328170627489_388. doc x @ 12387 @ @ 1

P703

[-01]

...

[-05]

Current last error

(Last current error 1...5)

S

0.0 ... 999.9 A

This parameter stores the output current that was being delivered at the time the fault occurred.
The values of the last 5 errors are stored.

The SimpleBox / ControlBox must be used to select the corresponding memory location 1...5-
(Array parameter), and confirmed using the OK / ENTER key to read the stored error code.

Pos : 330 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P700-P799/ Paramet er P704 – Spannung letzt e Stör ung 1. .. 5 @ 0\ mod_1328170671391_388.doc x @ 12410 @ @ 1

P704

[-01]

...

[-05]

Volt. last error
(Last voltage error 1...5)

S

0 ... 600 V AC

This parameter stores the output voltage that was being delivered at the time the fault occurred.
The values of the last 5 errors are stored.

The SimpleBox / ControlBox must be used to select the corresponding memory location 1...5-
(Array parameter), and confirmed using the OK / ENTER key to read the stored error code.

Pos : 331 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P700-P799/ Paramet er P705 – Z wischenkreiss pannung l etzt e St örung 1... 5 @ 0\ mod_1328170720639_388. doc x @ 12433 @ @ 1

P705

[-01]

...

[-05]

Last link circuit error

(Last link circuit error 1...5)

S

0 ... 1000 V DC

This parameter stores the link voltage that was being delivered at the time the error occurred. The
values of the last 5 errors are stored.

The SimpleBox / ControlBox must be used to select the corresponding memory location 1...5-
(Array parameter), and confirmed using the OK / ENTER key to read the stored error code.

Pos : 332 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P700-P799/ Paramet er P706 – Paramet ersat z letzt e St örung 1... 5 @ 0\ mod_1328170810570_388. doc x @ 12456 @ @ 1