NORD Drivesystems BU0500 User Manual

Page 144

Advertising
background image

SK 500E – Users Manual for Frequency Inverters

144

BU 0500 GB-1013

E011

11.0

Customer interface

Error in analog-digital converter

•

Internal customer unit (internal data bus) faulty or
damaged by radio radiation (EMC)

•

Check control terminals connection for short-circuit.

•

Minimize EMC interference by laying control and
power cables separately.

•

Earth the devices and shields well.

Pos : 410 /Anleit ungen/6. / 7. Mel dungen z um Betriebsz ust and [BU 0500 / BU 0200]/ St örmel dungen/F ehl er E012 [ SK 5xxE] @ 2\ mod_1361524186547_388. doc x @ 59066 @ @ 1

E012

12.0

External watchdog

The Watchdog function is selected at a digital input and the
impulse at the corresponding digital input is not present for
longer than the time set in parameter P460 >Watchdog
time<.

•

Check connections

•

Check P460 setting

12.1

Motor limit

"Motor switch-off limit"

The motor switch-off limit P534 [-01] has triggered.

•

Reduce load on motor

•

Set higher value in (P534 [-01]).

12.2

Generator limit

"Generator switch-off limit"

The generator switch-off limit P534 [-02] has triggered.

•

Reduce load on motor

•

Set higher value in (P534 [-02]).

12.5

Load limit

Switch-off due to overshooting or undershooting of
permissible load torques ((P525) … (P529)) for the time set
in (P528).

•

Adjust load.

•

Change limit values ((P525) ... (P527)).

•

Increase delay time (P528).

•

Change monitoring mode (P529).

12.8

Analog In minimum

Switch-off due to undershooting of the 0% adjustment value
(P402) with setting (P401) "0-10V with switch-off on error 1"
or "....2"

12.9

Analog In maximum

Switch-off due to overshooting of the 100% adjustment
value (P402) with setting (P401) "0-10V with switch-off on
error 1" or "....2"

Pos : 411 /Anleit ungen/6. / 7. Mel dungen z um Betriebsz ust and [BU 0500 / BU 0200]/ St örmel dungen/F ehl er E013 [ SK 180E ... SK 5xxE] @ 2\ mod_1347454271218_388.doc x @ 46751 @ @ 1

E013

13.0

Encoder error

No signal from encoder

•

Check 5V sensor if present.

•

Check supply voltage of encoder.

13.1

Speed slip error

"Speed slip error"

The slip speed error limit was reached.

•

Increase setting in P327.

13.2

Shut-down monitoring

The slip error monitoring has triggered; the motor could not
follow the setpoint.

•

Check motor data P201-P209! (Important for the
current controller)

•

Check motor circuit.

•

In servo mode, check the encoder setting P300 and
check the following

•

Increase setting value for torque limit in P112.

•

Increase setting value for current limit in P536.

•

Check deceleration time P103 and extend if
necessary

13.5

Reserved

Error message for POSICON

à see supplementary

instructions

13.6

Reserved

Error message for POSICON

à see supplementary

instructions

Pos : 412 /Anleit ungen/6. / 7. Mel dungen z um Betriebsz ust and [BU 0500 / BU 0200]/ St örmel dungen/F ehl er E014 "res er viert" [ SK 180E ... SK 5xxE] @ 2\ mod_1347454273854_388.doc x @ 46776 @ @ 1