NORD Drivesystems BU0500 User Manual

Page 154

Advertising
background image

SK 500E – Users Manual for Frequency Inverters

154

BU 0500 GB-1013

FI type (size 5/ 6):

SK 5xxE…

-112-340-A

-152-340-A

-182-340-A

-222-340-A

Nominal motor power

(4-pole standard motor)

400V

11.0 kW

15.0 kW

18.5 kW

22.0 kW

480V

15 hp

20 hp

25 hp

30 hp

Input

Mains voltage

3~ 400V

3 AC 380 ... 480V, -20% / +10%, 47 ... 63 Hz

Input current

rms

33.6 A

43.4 A

53.2 A

64.4 A

FLA

29.4 A

37.8 A

47.6 A

56.0 A

Recommended
mains fuse*

1 AC slow-acting

40 A

50 A

60 A

60 A

CB

40 A

50 A

60 A

60 A

Permissible mains
fuses for UL*

Fuse, 600V

60 A

60 A

60 A

60 A

Bussmann

FRS-R-40

FRS-R-50

FRS-R-60

FRS-R-60

CB

60 A

60 A

60 A

60 A

O

ut

put

Output voltage

3~ 400V

3 AC 0 - Mains voltage

Output current

rms

24.0 A

31.0 A

38.0 A

46.0 A

FLA

21.0 A

27.0 A

34.0 A

40.0 A

Min. braking resistor

Accessories

29

W

23

W

18

W

15

W

Type of ventilation

Fan cooling, temperature-controlled Switching thresholds:

ON= 57°C OFF=47°C

Weight

Approx. [kg]

8

10.3

* see also Section 1.5.2. Fuses: High-Interrupting Capacity, Current Limiting Classes (z.B. R, J, …), circuit breaker (CB): Inverse Time Trip Type

FI type (size 7/ 8):

SK 5xxE…

-302-340-A

-372-340-A

-452-340-A

-552-340-A

Nominal motor power

(4-pole standard motor)

400V

30.0 kW

37.0 kW

45.0 kW

55.0 kW

480V

40 hp

50 hp

60 hp

75 hp

Input

Mains voltage

3~ 400V

3 AC 380 ... 480V, -20% / +10%, 47 ... 63 Hz

Input current

rms

84.0 A

105.0 A

126.0 A

154 A

FLA

72.8 A

91.0 A

107.8 A

134.4 A

Recommended mains
fuse*

1 AC slow-

acting

100 A

100 A

125 A

160 A

CB

100 A

100 A

-

-

Permissible mains
fuses for UL*

Fuse, 600V

100 A

100 A

125 A

150 A

Bussmann

FRS-R-100

FRS-R-100

FRS-R-125

FRS-R-150

CB

100 A

100 A

-

-

O

ut

put

Output voltage

3~ 400V

3 AC 0 - Mains voltage

Output current

rms

60.0 A

75.0 A

90.0 A

110.0 A

FLA

52.0 A

65.0 A

77.0 A

96.0 A

Min. braking resistor

Accessories

9

W

9

W

8

W

8

W

Type of ventilation

Fan cooling, temperature-controlled Switching thresholds:

ON= 57°C OFF=47°C

Fan speed control

between 47°C and approx. 70°C

Weight

Approx. [kg]

16

20

* see also Section 1.5.2. Fuses: High-Interrupting Capacity, Current Limiting Classes (z.B. R, J, …), circuit breaker (CB): Inverse Time Trip Type