Enclosure management commands 116

The <asset tag> must be 0 to 32 characters long and includes all alphanumeric, underscore (_), and

dash (-) characters.

SET ENCLOSURE NAME

Command:
SET ENCLOSURE NAME "<enclosure name>"

Description:

o

Changes the enclosure name

o

The default enclosure name is the mid-plane serial number

Access level/Bay level:
OA administrator, OA operator

Restrictions:
The <enclosure name> must be 1 to 32 characters long and includes all alphanumeric, underscore (_),
and dash (-) characters.

SET ENCLOSURE PART_ NUMBER

Command:
SET ENCLOSURE PART_NUMBER "<part number>"

Description:
Sets the part number of the enclosure

Access level/Bay level:
OA administrator

Restrictions:
Must be 10 characters in length and the first character must be a digit. Acceptable characters are all
alphanumeric and the dash (-).

SET ENCLOSURE PDU_TYPE

Command:
SET ENCLOSURE PDU_TYPE {1|2|3|4|5}

Description:
Sets the enclosure PDU type to:

o

1=Single-phase

o

2=Three-phase

o

3=Three-phase, international

o

4=DC Power Input Module

o

5=Single phase IPD

Access level/Bay level:

Advertising