background image

Blade management commands 164

Power OK

Cooling OK

Location OK

Device Failure OK

Device Degraded OK

Blade #3 Status:

Power: No Server Blade Installed

Blade #4 Status:

Power: No Server Blade Installed

Blade #5 Status:

Server Blade Type: Bay Subsumed

Blade #6 Status:

Server Blade Type: Bay Subsumed

Blade #7 Status:

Power: On

Current Wattage used: 153

Health: Degraded

Unit Identification LED: On

Diagnostic Status:

Internal Data OK

Management Processor OK

I/O Configuration OK

Power OK

Cooling OK

Location OK

Device Failure OK

Device Degraded Failed

iLO Network OK

IML Reported Main Memory Errors

Uncorrectable Memory Error

Processor 1, Memory Module 2

Corrected Memory Error threshold exceeded

Processor 1, Memory Module 2

Example of Power Management Controller Error:

OA-00215AB0DAF1> show server status 12

Blade #12 Status:

Power: On

Current Wattage used: 143

Health: Other Unit Identification

LED: Off Virtual

Fan: 27%

Diagnostic Status:

Internal Data

OK

Management Processor OK

I/O Configuration

OK

Power

OK

Cooling

OK

Location

OK

Device Failure

OK

Device Degraded

OK

iLO Network

OK

Power Mgmt Cntlr

Other

SHOW SERVER TEMP