Set interconnect admin_password factory, Set interconnect factory – HP Onboard Administrator User Manual

Page 170

Advertising
background image

Interconnect management commands 170

SET INTERCONNECT ADMIN_PASSWORD

FACTORY

Command:
SET INTERCONNECT ADMIN_PASSWORD FACTORY [<bay number>]

Description:
Causes the interconnect to change the Administrator password to the factory default. When you issue
the command, you are prompted to confirm that this is your intention. To proceed with the change,
answer YES. Upon successful execution of the command, the following message is logged to the

Onboard Administrator syslog:
OA: Interconnect module x Admin password has been reset by user Administrator.


If the interconnect does not support the command, the Onboard Administrator displays the following
message:
This command is not supported by the interconnect.

Access level/Bay level:
Administrator
Bay specific

Restrictions:
You must have access to the specified bay number.

SET INTERCONNECT FACTORY

Command:
SET INTERCONNECT FACTORY [<bay number>]

Description:

o

Causes the interconnect to perform a factory reset, restoring all settings to their factory defaults.

o

Causes the Administrator password to be reset to the default factory password.

o

All configuration data and connections will be lost. You are prompted to confirm that you want to
restore factory settings. To proceed with the change, answer YES. Upon successful execution of the

command, the following message is logged to the Onboard Administrator syslog:
OA: Interconnect module x has been Factory Reset by user Administrator.

IMPORTANT:

Before resetting factory defaults, save your configuration.

o

If the interconnect does not support the command, the Onboard Administrator displays the following
message:
This command is not supported by the interconnect.

Access level/Bay level:
Administrator
Bay specific

Advertising