Enclosure management commands 126

Spare Part Number: XXXXXX-001

Product Ver:

Diagnostic Status:

Internal Data OK

Device Failure OK

Power Cord OK

SHOW ENCLOSURE STATUS

Command:
SHOW ENCLOSURE STATUS

Description:
Displays the basic health and status of the enclosure subsystem

Access level/Bay level:
All

Restrictions:
None

Example:

OA-0018FE27577F> SHOW ENCLOSURE STATUS

Enclosure:

Status: OK

Unit Identification LED: Off

Diagnostic Status:

Internal Data OK

Onboard Administrator:

Status: OK

Power Subsystem:

Status: OK

Power Mode: Not Redundant

Power Capacity: 3600 Watts DC

Power Available: 2685 Watts DC

Present Power: 463 Watts AC

Cooling Subsystem:

Status: OK

Fans Good/Wanted/Needed: 6/6/5

Fan 1: 9497 RPM (53%)

Fan 2: 7342 RPM (41%)

Fan 3: 9493 RPM (53%)

Fan 4: 9495 RPM (53%)

Fan 5: 7343 RPM (41%)

Fan 6: 9508 RPM (53%)