General management commands 55

SET FACTORY

Command:
SET FACTORY

Description:

o

Restores the Onboard Administrator to its factory defaults. The Administrator account password
does not change.

o

The Onboard Administrator restarts after all changes are made.

o

All existing settings are lost when this operation is run.

IMPORTANT:

Before resetting factory defaults, save your configuration. To upload a script

containing your current configuration, use the UPLOAD CONFIG (on page

139

) command. You

can use this script later to restore settings that are lost after a factory reset.

NOTE:

After a factory reset, the enclosure IPv6 network settings (IPv6, SLAAC, and DHCPv6) are

enabled by default.

Access level/Bay level:
OA administrator

Restrictions:
You cannot run SET FACTORY in FIPS Mode ON/DEBUG.

SET SCRIPT MODE

Command:
SET SCRIPT [MODE] {ON | OFF}

Description:

o

This command ceases all prompting and verifying of entries when SCRIPT MODE is on.

o

The ADD USER command must have a password argument if executed in SCRIPT MODE.

o

Default values are used for any parameters that would normally require user interaction.

o

This setting is only effective for the current CLI session.

Access level/Bay level:
All

Restrictions:
None

SET URB

Command:

SET URB [ URL | INTERVAL | PROXY URL | SMTPSERVER | MAILBOX ]

Description:
Sets settings for URB reporting
SET URB URL { <url> } sets the URB endpoint URL.