Set server powerdelay, Set server uid – HP Onboard Administrator User Manual

Page 156

Advertising
background image

Blade management commands 156

Description:

o

Stores a setting for the IPL to be passed to the specified servers at the next reboot.

o

HDD sets Hard Disk Drive as the boot device to be used on the next boot.

o

PXE sets the PXE Server as the boot device to be used on the next boot.

o

RBSU sets the ROM Based Setup Utility as the boot device to be used on the next boot.

o

Sets the boot device to be used on the next boot of the bays specified.

Access level/Bay level:
OA administrator, OA operator
Bay specific

Restrictions:

o

You must have access to the specified bay number.

o

This command is not applicable to storage blades.

o

This command is not applicable to HP Integrity server blades.

o

This setting is valid only on present blades and is cleared if the blade is removed.

o

This version of Onboard Administrator firmware does not support boot options for servers
configured in UEFI boot mode.

SET SERVER POWERDELAY

Command:
SET SERVER POWERDELAY {ALL | <bay number> [{ - | , } <bay number>]} {number

of seconds to delay power | NOPOWERON}

Description:
Set the PowerDelay status for the specified server or range of servers. If the delay is zero, the delay has
no effect on the device. If the delay is NOPOWERON, the device cannot poweron until all devices have

completed their delays.

Access level/Bay level:
Administrator
Bay specific

Restrictions:
You must have access to the specified bay number.

SET SERVER UID

Command:
SET SERVER UID {ALL | <bay number> [{ - | , } <bay number>]} {ON | OFF}

Description:
Turns a server blade UID LED on or off

Access level/Bay level:
All