Set enclosure serial_number, Set enclosure uid, Set llf interval – HP Onboard Administrator User Manual
Page 117

Enclosure management commands 117
OA administrator
•
Restrictions:
1, 2, 3, 4, 5
SET ENCLOSURE SERIAL_NUMBER
•
Command:
SET ENCLOSURE SERIAL_NUMBER "<serial number>"
•
Description:
Sets the enclosure serial number.
•
Access level/Bay level:
OA administrator
•
Restrictions:
o
Must be 10 characters in length. Acceptable characters include alphanumeric, dash, and
underscore.
o
Remote Support must be disabled. For more information, see the DISABLE REMOTE_SUPPORT (on
) command.
SET ENCLOSURE UID
•
Command:
SET ENCLOSURE UID {ON | OFF}
•
Description:
Turns the UID LED of the enclosure on or off.
•
Access level/Bay level:
OA administrator, OA operator
•
Restrictions:
None
SET LLF INTERVAL
•
Command:
SET LLF INTERVAL <seconds>
•
Description:
Set the Link Loss Failure Interval
•
Access level/Bay level:
Operator, Administrator
Restrictions:
Must have OA permission to perform this command.