Set session timeout, Set user access, Set user contact – HP Onboard Administrator User Manual

Page 29

Advertising
background image

User account commands 29

o

When in FIPS Mode OFF, the character set includes all printable characters. When in FIPS Mode

ON/DEBUG, the password must contain at least one character from three of the four types of
characters. The four types are upper-case, lower-case, numeric, and non-alphanumeric.

SET SESSION TIMEOUT

Command:
SET SESSION TIMEOUT <timeout>

Description:
Sets the number of minutes before inactive sessions are removed. The default setting is 1440.

Access level/ Bay level:
OA administrator

Restriction:
Valid session timeout values range from 10 to 1440 minutes (24 hours).

SET USER ACCESS

Command:
SET USER ACCESS "<user name>" {ADMINISTRATOR | OPERATOR | USER}

Description:
Sets the user access level. Additionally, use the ASSIGN command to give the user access rights to the

Onboard Administrator, server bays, and interconnect bays.

Access level/Bay level:
OA administrator

Restrictions:
None

SET USER CONTACT

Command:
SET USER CONTACT ["<user name>"] "<contact info>"

Description:
Sets the contact information field for the user. If there is no <user name>, the command modifies the
contact information of the user who executed the command.

Access level/Bay level:

o

All users can modify their own contact information.

o

The OA administrator can modify all users.

Restrictions:

o

The <user name> is case sensitive. The <contact info> must be a maximum of 20 characters long
and includes all alphanumeric characters, the dash, the underscore, and spaces.

o

The default contact information is blank.