SECTION 1 - SPECIFICATIONS
3121265
– JLG Lift –
1-9
7.
Hydraulic Oil
Lube Point(s) - Fill Cap
Capacity - 55 gallons (208 liters) Tank
Lube - HO
Interval - Check level daily. Change every 2 years or
1200 hours of operation.
8.
Suction Strainers (In Tank)
Lube Point(s) - 2
Interval - Every 2 years or 1200 hours of operation.
Remove and clean at time of hydraulic oil
change.
9.
Oil Change w/Filter - Deutz
Lube Point(s) - Fill Cap/Spin-on Element
Capacity -
5 Quarts (4.5 L) Cooling System
11 Quarts (10.5 L) w/Filter
16 Quarts (15 L) Total Capacity
Lube - EO
Interval - Check level daily; change every 500 hours
or six months, whichever comes first. Adjust final
oil level by mark on dipstick
FULL LEVEL (HOT OIL)
FULL LEVEL (COLD OIL)