JLG 1100SB Service Manual User Manual

Page 25

Advertising
background image

SECTION 1 - SPECIFICATIONS

3121265

– JLG Lift –

1-9

7.

Hydraulic Oil

Lube Point(s) - Fill Cap
Capacity - 55 gallons (208 liters) Tank
Lube - HO
Interval - Check level daily. Change every 2 years or

1200 hours of operation.

8.

Suction Strainers (In Tank)

Lube Point(s) - 2
Interval - Every 2 years or 1200 hours of operation.

Remove and clean at time of hydraulic oil
change.

9.

Oil Change w/Filter - Deutz

Lube Point(s) - Fill Cap/Spin-on Element
Capacity -
5 Quarts (4.5 L) Cooling System
11 Quarts (10.5 L) w/Filter
16 Quarts (15 L) Total Capacity
Lube - EO
Interval - Check level daily; change every 500 hours

or six months, whichever comes first. Adjust final
oil level by mark on dipstick

FULL LEVEL (HOT OIL)

FULL LEVEL (COLD OIL)

Advertising