JLG 1100SB Service Manual User Manual

Page 371

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

3121265

– JLG Lift –

6-87

33135

33

135

PLATFORM CONTROL VALVE - SHORT TO BATTERY

There is a Short to Battery
to the Platform Control
Valve.

- Electronic leveling system
equipped vehicles only.

33136

33

136

MAIN LIFT APU VALVE - SHORT TO GROUND

There is a Short to Ground
to the Main Lift APU Valve.

- 1250AJP only.

33137

33

137

MAIN LIFT APU VALVE - OPEN CIRCUIT

There is an Open Circuit to
the Main Lift APU Valve.

- 1250AJP only.

33138

33

138

MAIN LIFT APU VALVE - SHORT TO BATTERY

There is a Short to Battery
to the Main Lift APU Valve.

- 1250AJP only.

33139

33

139

MAIN LIFT PILOT - PRESSURE FAILURE

The Main Lift Pilot has a
Pressure Failure.

- 1250AJP only.

33140

33

140

MAIN LIFT PILOT - NO PRESSURE

The Main Lift Pilot has No
Pressure.

- 1250AJP only.

33141

33

141

MAIN LIFT PILOT - PRESSURE SWITCH FAILURE

The Main Lift Pilot has a
Pressure Switch Failure.

- 1250AJP only.

33142

33

142

TOWER LIFT APU VALVE - STUCK OPEN

The Tower Lift APU Valve
is Stuck Open

- 1250AJP only.

33143

33

143

TOWER LIFT ENABLE VALVE - STUCK OPEN

The Tower Lift Enable
Valve is Stuck Open

- 1250AJP only.

33144

33

144

TOWER LIFT ENABLE VALVE - SHORT TO GROUND

There is a Short to Ground
to the Tower Lift Enable
Valve.

- 1250AJP only.

33145

33

145

TOWER LIFT ENABLE VALVE - OPEN CIRCUIT

There is an Open Circuit to
the Tower Lift Enable
Valve.

- 1250AJP only.

33146

33

146

TOWER LIFT ENABLE VALVE - SHORT TO BATTERY

There is a Short to Battery
to the Tower Lift Enable
Valve.

- 1250AJP only.

33147

33

147

TOWER TELESCOPE APU VALVE - SHORT TO GROUND

There is a Short to Ground
to the Tower Telescope
APU Valve.

- 1250AJP only.

33148

33

148

TOWER TELESCOPE APU VALVE - OPEN CIRCUIT

There is an Open Circuit to
the Tower Telescope APU
Valve.

- 1250AJP only.

33149

33

149

TOWER TELESCOPE APU VALVE - SHORT TO BATTERY

There is a Short to Battery
to the Tower Telescope
APU Valve.

- 1250AJP only.

33150

33

150

LIFT PILOT VALVE - SHORT TO GROUND

There is a Short to Ground
to the Lift Pilot Valve.

- Gravity Lift Down equipped
vehicles only.

33151

33

151

LIFT PILOT VALVE - OPEN CIRCUIT

There is an Open Circuit to
the Lift Pilot Valve.

- Gravity Lift Down equipped
vehicles only.

33152

33

152

LIFT PILOT VALVE - SHORT TO BATTERY

There is a Short to Battery
to the Lift Pilot Valve.

- Gravity Lift Down equipped
vehicles only.

33153

33

153

LIFT DOWN AUX VALVE - SHORT TO GROUND

There is a Short to Ground
to the Lift Down Auxiliary
Valve.

- Gravity Lift Down equipped
vehicles only.

Table 6-6. Diagnostic Trouble Code Chart

DTC

Flash

Code

Sequence

Fault Message