JLG 1100SB Service Manual User Manual

Page 379

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

3121265

– JLG Lift –

6-95

826

82

6

RUNNING AT CREEP - PLATFORM OVERLOADED

All functions at creep, the
Load Sensing System indi-
cates the Platform is over-
loaded AND is configured
to warn only while the Plat-
form is overloaded.

827

82

7

DRIVE & BOOM PREVENTED - PLATFORM OVER-
LOADED

Driving and boom func-
tions are not possible while
the Load Sensing System
indicates the Platform is
overloaded AND is config-
ured to prevent drive and
boom functions while the
Platform is overloaded.

828

82

8

LIFT UP & TELE OUT PREVENTED - PLATFORM OVER-
LOADED

Lift up and telescope out
are not possible while the
Load Sensing System indi-
cates the Platform is over-
loaded AND is configured
to prevent Lift up and tele-
scope out while the Plat-
form is overloaded.

830

83

0

<<< PLATFORM LEVELING >>>

831

83

1

PLATFORM LEVELING OVERRIDE ON

Platform Leveling forced
on with Access Level 0
selection.

832

83

2

PLATFORM LEVELING OVERRIDE OFF

Platform Leveling forced
off with Access Level 0
selection.

833

83

3

PLATFORM LEVEL UP CRACKPOINT - NOT CALIBRATED The Platform Level Up

Valve Crackpoint has not
been calibrated.

- Electronic leveling system
equipped vehicles only.

834

83

4

PLATFORM LEVEL DOWN CRACKPOINT - NOT CALI-
BRATED

The Platform Level Down
Valve Crackpoint has not
been calibrated.

- Electronic leveling system
equipped vehicles only.

837

83

7

PLATFORM LEVEL SENSOR #1 - SHORT TO BATTERY

There is a Short to Battery
to the Platform Level Sen-
sor #1.

- Electronic leveling system
equipped vehicles only.

838

83

8

PLATFORM LEVEL SENSOR #1 - SHORT TO GROUND OR
OPEN CIRCUIT

There is a Short to Ground
or an Open Circuit to the
Platform Level Sensor #1.

- Electronic leveling system
equipped vehicles only.

8311

83

11

PLATFORM LEVEL SENSOR #2 - SHORT TO BATTERY

There is a Short to Battery
to the Platform Level Sen-
sor #2.

- Electronic leveling system
equipped vehicles only.

8312

83

12

PLATFORM LEVEL SENSOR #2 - SHORT TO GROUND OR
OPEN CIRCUIT

There is a Short to Ground
or an Open Circuit to the
Platform Level Sensor #2.

- Electronic leveling system
equipped vehicles only.

Table 6-6. Diagnostic Trouble Code Chart

DTC

Flash

Code

Sequence

Fault Message

Fault Description

Check

Advertising