9 machine personality settings/ function speeds, Machine personality settings/function speeds -21, Personality ranges/defaults -21 – JLG 1100SB Service Manual User Manual

Page 305

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

3121265

– JLG Lift –

6-21

6.9 MACHINE PERSONALITY SETTINGS/

FUNCTION SPEEDS

NOTE: Personality settings can be adjusted within the

adjustment range in order to achieve optimum
machine performance.

Table 6-3. Personality Ranges/Defaults

SUBMENU

(DISPLAYED ON

ANALYZER 1ST

LINE)

PARAMETER

(DISPLAYED ON

ANALYZER 2

ND

LINE)

DESCRIPTION

RANGE

DEFAULT

VALUES

TIME RANGE

(SEC) (SEE

SECTION 6.10

FOR MACHINE

ORIENTATION

WHEN SETTING

SPEEDS)

DRIVE:

ACCEL X.Xs

Displays/adjusts drive acceleration

0.1 to 5.0 sec

2.0

DECEL X.Xs

Displays/adjusts drive deceleration

0.1 to 3.0 sec

1.3

MIN forward XX%

Displays/adjusts minimum forward
drive speed

0 to 35%

1

MAX forward XXX%

Displays/adjusts maximum forward
drive speed

0 to 100%

100

44-48

MIN reverse XX%

Displays/adjusts minimum reverse
drive speed

0 to 35%

1

MAX reverse XXX%

Displays/adjusts maximum reverse
drive speed

0 to 100%

100

44-48

ELEV. MAX XX%

Displays/adjusts maximum drive speed
NOTE: used when elevation cutout
switches are limiting maximum speed

0 to 50%

25

93-104

CREEP MAX XX%

Displays/adjusts maximum drive speed
NOTE: used when creep switch on
pump pot is active

0 to 50%

35

79-87

STEER:

max SPEED XXX%

Displays/adjusts maximum steer
speed.

0 to 100%

100

MAIN LIFT:

ACCEL X.Xs

Displays/adjusts main lift acceleration

0.1 to 5.0 sec

1.0

DECEL X.Xs

Displays/adjusts main lift deceleration

0.1 to 3.0 sec

1.0

MIN Up XX%

Displays/adjusts minimum main lift up
speed

0 to 60%

20

MAX UP XX%

Displays/adjusts maximum main lift up
speed

0 to 100%

50

75-100

MIN DOWN XX%

Displays/adjusts minimum main lift
down speed

0 to 60%

10

MAX DOWN XXX%

Displays/adjusts maximum main lift
down speed

0 to 100%

50

85-110

CREEP UP XX%

Displays/adjusts maximum main lift up
speed
NOTE: used when creep switch on
pump pot is active

0 to 65%

50

CREEP DOWN XX%

Displays/adjusts maximum main lift
down speed
NOTE: used when creep switch on
pump pot is active

0 to 75%

45

Advertising