JLG 1100SB Service Manual User Manual

Page 384

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

6-100

– JLG Lift –

3121265

850

85

0

<<< MOMENT / LOAD PINS >>>

851

85

1

MOMENT PIN - HORIZONTAL FORCE OUT OF RANGE

The Moment Pin horizontal
force is out of range.

852

85

2

MOMENT PIN - VERTICAL FORCE OUT OF RANGE

The Moment Pin vertical
force is out of range.

853

85

3

LOAD PIN - HORIZONTAL FORCE OUT OF RANGE

The Load Pin horizontal
force is out of range.

-1250

854

85

4

LOAD PIN - VERTICAL FORCE OUT OF RANGE

The Load Pin vertical force
is out of range.

-1250

855

85

5

MOMENT PIN - SENSOR FAULT

The Moment Pin has
reported a fault.

856

85

6

LOAD PIN - SENSOR FAULT

The Load Pin has reported
a fault.

-1250

857

85

7

NEW MOMENT PIN DETECTED

A new Moment Pin has
been detected.

858

85

8

NEW LOAD PIN DETECTED

A new Load Pin has been
detected.

-1250

859

85

9

LOAD PIN/TOWER LIFT CYLINDER ANGLE DISAGREE-
MENT

There is a disagreement
between the Load Pin and
the Tower Lift cylinder
Angle.

-1250

8510

85

10

LOAD PIN - FORCE VALUES NOT CHANGING

The Load Pin is not chang-
ing.

-1250

8511

85

11

LOAD PIN - FORCE TOO LOW OVER TOWER ANGLE
CHANGE

X

-1250

8512

85

12

LOAD PIN - FORCE TOO LOW OVER MAIN ANGLE
CHANGE

X

-1250

8513

85

13

LOAD PIN - FORCE TOO LOW OVER MAIN LENGTH TRAN-
SITION

X

-1250

860

86

0

<<< STEERING / AXLE >>>

861

86

1

RESTRICTED TO TRANSPORT - OSCILLATING AXLE
PRESSURE SWITCH DISAGREEMENT

The Oscillating Axle Pres-
sure Switch indicates pres-
sure while not driving or
does not indicate pressure
while driving and restricted
to transport.

- Electrically released Oscil-
lated Axles equipped vehi-
cles only.

862

86

2

AXLE EXTEND VALVE - SHORT TO BATTERY OR OPEN
CIRCUIT

There is a Short to Battery
or an Open Circuit to the
Axle Extend Valve.

863

86

3

AXLE EXTEND VALVE - SHORT TO GROUND

There is a Short to Ground
to the Axle Extend Valve.

864

86

4

AXLE RETRACT VALVE - SHORT TO BATTERY OR OPEN
CIRCUIT

There is a Short to Battery
or an Open Circuit to the
Axle Retract Valve.

865

86

5

AXLE RETRACT VALVE - SHORT TO GROUND

There is a Short to Ground
to the Axle Retract Valve.

Table 6-6. Diagnostic Trouble Code Chart

DTC

Flash

Code

Sequence

Fault Message

Fault Description

Check