Test from the ground station, Test from the ground station -29 – JLG 1100SB Service Manual User Manual

Page 313

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

3121265

– JLG Lift –

6-29

Test from the Ground Station

1.

Position the Platform/Ground select switch to the
Ground position.

2.

Plug the analyzer into the connector inside the
Ground control box.

3.

Pull out the Emergency Stop switch. and Start the
engine.

4.

The analyzer screen should read:

5.

Use the arrow button to reach SYSTEM TEST. Hit
Enter. The analyzer will prompt you asking if you
want to activate the system test; hit Enter again to
activate.

6.

Follow the flow path in Figure 6-13., System Test
Flow Chart - Ground Station Tests
and go through
the component tests. Hit the ESC key during any
part of the test to return to the main menu without
completing all tests or wait until all tests are com-
plete. During the TEST ALL INPUTS sequence, the
analyzer allows control switches to be operated and
shows if they are closed (CL) or open (OP).