SECTION 6 - JLG CONTROL SYSTEM

3121265

– JLG Lift –

6-85

3372

33

72

GROUND ALARM - OPEN CIRCUIT

There is an Open Circuit to
the Ground Alarm.

- Ground Alarm equipped
vehicles only.

3373

33

73

GEN SET/WELDER - SHORT TO GROUND

There is a Short to Ground
to the Generator Relay.

- Generator / Welder
equipped vehicles only.

3374

33

74

GEN SET/WELDER - OPEN CIRCUIT

There is an Open Circuit to
the Generator Relay.

- Generator / Welder
equipped vehicles only.

3375

33

75

GEN SET/WELDER - SHORT TO BATTERY

There is a Short to Battery
to the Generator Relay.

- Generator / Welder
equipped vehicles only.

3376

33

76

HEAD TAIL LIGHT - SHORT TO GROUND

There is a Short to Ground
to the Head Light Relay.

- Head Light equipped vehi-
cles only.

3377

33

77

HEAD TAIL LIGHT - OPEN CIRCUIT

There is an Open Circuit to
the Head Light Relay.

- Head Light equipped vehi-
cles only.

3378

33

78

HEAD TAIL LIGHT - SHORT TO BATTERY

There is a Short to Battery
to the Head Light Relay.

- Head Light equipped vehi-
cles only.

3379

33

79

HOUR METER - SHORT TO GROUND

There is a Short to Ground
to the Hour Meter.

3380

33

80

HOUR METER - OPEN CIRCUIT

There is an Open Circuit to
the Hour Meter.

- Can be reported during
power-up.

3381

33

81

HOUR METER - SHORT TO BATTERY

There is a Short to Battery
to the Hour Meter.

3385

33

85

PLATFORM LEVEL UP OVERRIDE VALVE - SHORT TO
GROUND

There is a Short to Ground
to the Platform Level Up
Override Valve.

- Electronic leveling system
equipped vehicles only.

3386

33

86

PLATFORM LEVEL UP OVERRIDE VALVE - OPEN CIR-
CUIT

There is an Open Circuit to
the Platform Level Up
Override Valve.

- Electronic leveling system
equipped vehicles only.

3387

33

87

PLATFORM LEVEL UP OVERRIDE VALVE - SHORT TO
BATTERY

There is a Short to Battery
to the Platform Level Up
Override Valve.

- Electronic leveling system
equipped vehicles only.

3391

33

91

PLATFORM LEVEL DOWN OVERRIDE VALVE - SHORT TO
GROUND

There is a Short to Ground
to the Platform Level Down
Override Valve.

- Electronic leveling system
equipped vehicles only.

3392

33

92

PLATFORM LEVEL DOWN OVERRIDE VALVE - OPEN CIR-
CUIT

There is an Open Circuit to
the Platform Level Down
Override Valve.

- Electronic leveling system
equipped vehicles only.

3393

33

93

PLATFORM LEVEL DOWN OVERRIDE VALVE - SHORT TO
BATTERY

There is a Short to Battery
to the Platform Level Down
Override Valve.

- Electronic leveling system
equipped vehicles only.

3394

33

94

PLATFORM ROTATE LEFT VALVE - SHORT TO GROUND

There is a Short to Ground
to the Platform Rotate Left
Valve.

3395

33

95

PLATFORM ROTATE LEFT VALVE - OPEN CIRCUIT

There is an Open Circuit to
the Platform Rotate Left
Valve.

3396

33

96

PLATFORM ROTATE LEFT VALVE - SHORT TO BATTERY

There is a Short to Battery
to the Platform Rotate Left
Valve.

Table 6-6. Diagnostic Trouble Code Chart

DTC

Flash

Code

Sequence

Fault Message

Fault Description

Check