4.

The analyzer screen should read:

5.

Use the arrow button to reach ACCESS LEVEL 2. Hit
Enter.

6.

Enter the Access Code, 33271.

7.

Go to the PERSONALITIES menu.

8.

Using the left arrow button, go to the GROUND
MODE menu.

9.

Hit ENTER.

10.

Using the UP/DOWN arrows, adjust the following
personalities to 100%.

Basket Rotate
Basket Level
Jib U/D (if configured)

Start up the machine and exercise each above plat-
form function (from the ground) eight (8) to ten (10)
times for 5 seconds in each direction.

11.

Return the personality settings back to the values as
shown in the Personality Ranges/Defaults table in
Section 6 - JLG Control System.

12.

Recycle EMS.

STEP 4: CALIBRATING THE PLATFORM
LEVEL UP AND DOWN VALVE CRACKPOINTS

1.

Position the Platform/Ground select switch to the
Ground position.

2.

Plug the analyzer into the connector inside the
Ground control box.

3.

Pull out the Emergency Stop switch and start the
engine.