18 calibrating tilt sensor, Calibrating tilt sensor -63 – JLG 1100SB Service Manual User Manual

Page 347

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

3121265

– JLG Lift –

6-63

15.

Hit Enter. The screen will read:

16.

Repeat steps 10 thru 12 for the Tele In function.

17.

After completing all the Tele Calibrations, hit ESC
twice to go back to CALIBRATIONS.

6.18 CALIBRATING TILT SENSOR

A NEW TILT MODULE WILL ACT AS IF IT IS TILTED ALL OF THE
TIME UNTIL THE FOLLOWING PROCEDURE IS PERFORMED.

DO NOT CALIBRATE THE LEVEL SENSOR EXCEPT ON A LEVEL
SURFACE.

1.

Use the following procedure to calibrate the tilt sen-
sor.

Before the tilt sensor can be calibrated, the following
conditions must be met:

a. Steering previously calibrated.

b. Axles extended.

c. Wheels straight.

d. Turntable centered.

e. Boom fully retracted.

f. Boom angle is less than 45°.

g. Machine on firm, level ground.

2.

Position the Platform/Ground select switch to the
Ground position.

Advertising