Step 2: calibrating the platform level sensors, Step 2: calibrating the platform level sensors -54 – JLG 1100SB Service Manual User Manual

Page 338

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

6-54

– JLG Lift –

3121265

7.

Use the arrow button to reach PERSONALITIES
adjust the following personalities. Refer to the Per-
sonality Ranges/Defaults table for proper setting val-
ues.

Basket Level Up Min
Basket Level Up Max
Basket Level Down Max
Jib Up Min
Jib Down Min

8.

Recycle EMS.

STEP 2: CALIBRATING THE PLATFORM
LEVEL SENSORS

1.

Position the Platform/Ground select switch to the
Ground position.

2.

Plug the analyzer into the connector inside the
Ground control box.

3.

Pull out the Emergency Stop switch and start the
engine.

4.

Manually level the platform with the switch on the
Main Terminal Box.

5.

The analyzer screen should read:

6.

Use the arrow button to reach ACCESS LEVEL 2. Hit
Enter.

7.

Enter the Access Code, 33271.

8.

Use the arrow button to reach CALIBRATIONS menu
and hit ENTER.

9.

Use right arrow go to PLAT. LEVELING screen.