SECTION 6 - JLG CONTROL SYSTEM

3121265

– JLG Lift –

6-127

Table 6-11. Load Moment Pin Troubleshooting: Moment Pin Horizontal Force Out of Range

STEP

FAULT CODE/SYMPTOM

REPAIR

YES

NO

1

8/6 MOMENT PIN HORIZONTAL FORCE OUT OF
RANGE The horizontal force is out of allowed
range.

Check to see if the platform is
overloaded in the vertical posi-
tion. Check the rated capacity
requirement.

Remove excess weight

Go to step 2

2

Check to see if any additional
accessories have been added to
the platform without proper cali-
bration.

Perform the Boom
Sensor calibration
process.

Go to step 3

3

Perform the BCS daily check
procedure to make sure the
boom sections are stopping
correctly at the witness marks
matching their capacity selec-
tion.

Go to step 4

Perform the Boom Sen-
sor calibration process.

4

Inspect the job the machine is
performing, making sure that
there is no additional force
applied when the boom sections
are in the horizontal position.
Also consider weather condi-
tions (Wind).

Go to step 5

Position machine cor-
rectly.

5

Use the Analyzer, scroll to the
DIAGNOSTICS menu, press
ENTER, then scroll to the
MOMENT menu, and press
ENTER, check to see if Actual /
Over / Under moment values are
registering on the screen dis-
play.

Go to step 6

Replace the load moment
pin. & Perform the Boom
Sensor calibration pro-
cess.

6

If they are, refer to Figure 6-32.,
Moment Chart for com
parable
values, if the values are not
close, try boom sensor calibra-
tion to see if the values come
within the chart.

If the problem still exists,
verify steps 1-6 again
before contacting the JLG
Service Dept.

Replace the load moment
pin. & Perform the Boom
Sensor calibration pro-
cess.