Figure 6-27. CANbus Connections - Sheet 2 of 5

1. Chassis Module CANbus Link
2. Ground Module CANbus Link
3. Boom Length & Angle Module
4. BLAM J1 (Gray) Plug
* Remove BLAM J1 Plug and measure the A & B pin of the T fit-
ting. This should measure approximately 60 Ohms for a complete
CANbus Circuit.