JLG 1100SB Service Manual User Manual

Page 304

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

6-20

– JLG Lift –

3121265

FUNCTION CUTOUT:
14*

0

1

2

3

NO: No drive cutout.

BOOM CUTOUT: Boom function cutout while driving above elevation.

DRIVE CUTOUT: Drive cutout above elevation.

DRIVE CUT E&T: Drive cutout above elevation and tilted.

0

* Only visible under certain market selections.

* Certain market selections will limit function cutout options or alter default setting.

GROUND ALARM:
15*

0

1

2

3

NO: No ground alarm installed.

DRIVE: Travel alarm sounds when the drive function is active (Option).

DESCENT: Descent alarm sounds when lift down is active (Option).

MOTION: Motion alarm sounds when any function is active (Option).

0

* Certain market selections will alter default setting.

OSCILLATING AXLE:
16

0

1

NO: No oscillating axle system installed.

YES: Oscillating axle system installed.

1

TEMPERATURE:
17*

0

1

CELSIUS: Celsius unit selection.

FAHRENHEIT: Fahrenheit unit selection.

1

* Certain market selections will alter default setting.

4150364-17

Table 6-2. Machine Configuration Programming Information - Version P7.X to Present

Configuration Digit

Number

Description

Default

Number