3121265

– JLG Lift –

6-105

9942

99

42

BLAM BACKUP COMMUNICATIONS LINK FAULTY

The BLAM backup com-
munications link test was
activated at startup, but no
communication connec-
tion established/main-
tained.

- BLAM equipped vehicles
only.
-1250

9943

99

43

BLAM BACKUP COMMUNICATIONS LOST - HYDRAULICS
SUSPENDED

The BLAM backup com-
munications link was acti-
vated, but no
communication connec-
tion established/main-
tained.

- BLAM equipped vehicles
only.
-1250

9944

99

44

CURRENT FEEDBACK GAINS OUT OF RANGE

The factory set current
feedback gains are out of
range.

9945

99

45

CURRENT FEEDBACK CALIBRATION CHECKSUM
INCORRECT

The factory set current
feedback checksum is not
correct.

9975

99

75

LOAD PIN NOT CALIBRATED

The Load Pin has not been
calibrated.

-1250

9979

99

79

FUNCTIONS LOCKED OUT - GROUND MODULE SOFT-
WARE VERSION IMPROPER

Temporary fault for the
telematics project. The
model needs to be a 600S
or 1350S if not this fault will
be generated and Platform
controls will be prevented.
This fault was to insure that
the software will only work
for these two models.

Table 6-6. Diagnostic Trouble Code Chart