Drive PLC Developer Studio

Working with projects and objects

6-38

l

DDS EN 2.3

The following channels to the automation system are currently available for practical use:

Local gateway

Remote gateway
Via a TCP/IP network to a remote gateway PC with parallel port and dongle.

PC_lokal

PC_x

PC_Gateway

TCP/IP

/

‘local (shared memory)'

PC_PLC1

PC_PLC2

PC_PLC3

PC_PLC4

TPC/IP,

Pipe,

etc.

The dialog box

Communication parameters

is divided into four panes:

1. Channels

This is where the communication channels from the local host are displayed and those to be edited
are selected.

2. Communication driver display

The currently loaded communication driver (e. g. “CAN 8220 | JumpingLEDs.pro”).

3. Communication parameters

The parameters set for the currently loaded communication driver.

4. Buttons

OK

Quit and accept parameters

Cancel

Quit and reject parameters

New...

Create a new communication channel, via the parallel port/system bus dongle, for example

Remove

Remove a channel selected in pane

Channels

Gateway

Create a new communication channel to a remote gateway PC

Update

Check parameters or update the display

Creating a communication channel via the system bus dongle

The most commonly used communication option is via the system bus dongle connected to a local
PC via the parallel port.

Two parameters must be known to establish a connection to a certain automation system (e. g. 9300
Servo PLC
) within a CAN bus network:

The device address on the bus (CAN bus node address). The device address is stored in code
C0350 of the automation system and must match the setting of the communication channel.

The baud rate set on the bus (CAN bus baud rate). The device address is stored in code
C0351 of the automation system and must match the setting of the communication channel.