The following example shows a step whose processing is to take a minimum of two and a maximum
of ten seconds.

7.8.3.7

Time limit overview

Icon:

-

Menu:

ExtrasWTime limit overview

Keyboard:

-

Use this command to open the dialog box

Time limit overview to edit the time settings for your SFC

steps.

The dialog box

Time limit overview displays all steps of your SFC organization unit.

If a time limit has been entered for a step, it will be shown to the right of the step (minimum limit first,
then maximum limit).

Edit time limits

Time limits can be edited:

1. Click the required step in the overview. The step name is displayed at the bottom of the

window.

2. Use input fields Minimal time / Maximal time to specify the required time limit (constant or

variable of type TIME), e. g. T#3s.

3. Click OK to close the dialog box and save the changes.