Drive PLC Developer Studio

Resources

8-16

l

DDS EN 2.3

Example: Instances of the function block L_DIGDEL of the 9300 Servo PLC

Variable name

L_DIGDEL1

L_DIGDEL2

Setting range

Lenze

byFunction

C0720

0 ... 2

2

y

C0725

0

wDelayTime

C0721

C0726

0.001 ... 60.000 s

1.000

Tip!

Parameter variables can only be read in the PLC program, not written.

Example:

LD L_DIGDEL1.byFunction
ST variable_x

The VAR CONSTANT RETAIN variable can only be accessed via the assigned code.

Use the FB L_ParWrite from the function library ” LenzeDrive.lib” to write codes in PLC
programs.

Accepting all Lenze codes of a function block

Open the dialog box

Instance Parameter Manager and click the button First instance to assign the

associated code only to the selected variable.

To accept all Lenze codes of the function block instance, select a variable of the associated function
block in the Instance Parameter Manager and click Insert

WAdapt Lenze initial codes.

This command is also available in the shortcut menu:

Command execution creates all codes of the function block instance in the Instance Parameter
Manager (in this example: L_DIGDEL1.wDelayTime):

8.4.3.6

Accessing arrays via subcodes

Access to individual array fields by means of codes (e. g. using the Keypad, for example) is via
so-called subcodes.

Subcodes are a code subset of a master code.

Example:

C6000

Master code

C6000/1

Subcode 1

C6000/2

Subcode 2

... ...

C6000/n

Subcode n