4 system-oriented communication error, System-oriented communication error, Drive plc developer studio – Lenze DDS v2.3 User Manual

Page 332: Appendix

Advertising
background image

Drive PLC Developer Studio

Appendix

15-22

l

DDS EN 2.3

No.

Possible remedy

Cause

41729
(A301)

Error when writing an OPC item.

Contact Lenze

41730
(A302)

Internal program error
OPC item could not be read.

Restart the application.
Use the system bus configurator to check if the target system responds.

41731
(A303)

Internal program error
OPC connections failed.

Install the CAN driver update.
If the problem still exists, contact Lenze.

41732
(A304)

Internal program error
OPC connection point for asynchronous communication
could not be created.

Install the CAN driver update.
If the problem still exists, contact Lenze.

41733
(A305)

Internal program error
OPC item could not be deleted.

Restart the application.

41734
(A306)

Internal program error
OPC item list could not be deleted.

Restart the application.

45569
(B201)

The target system has an H05 trip.
Internal fault.

Contact Lenze.

45570
(B202)

The target system has a PR0 trip.
Parameter set error

Reset the trip.

45571
(B203)

The target system has a PER trip.
Program failure

Reset the trip. (Mains disconnection)

45572
(B204)

The target system has a CCR trip.
System failure

Reset the trip. (Mains disconnection)

45573
(B205)

The target system has an unknown error.

Contact Lenze.

45574
(B206)

The software version of the target system does not
correspond to the program to be loaded.

Use the corresponding target system.

45575
(B207)

The target system is write-protected.

Remove the write protection for downloading.

45576
(B208)

Controller is not inhibited in the target system.

Inhibit the controller.

45577
(B209)

PLC program did not stop.

Stop the PLC program.

45578
(B20A)

The program to be loaded is too large for the target
system.

Reduce the program size.
Split the program.

45579
(B20B)

The target system has not enough
technology units.

Use an xT variant as a target system,
e.g. EVS93xx-xT.

45580
(B20C)

The preparations for the program transfer have failed.

Reactivate the program transfer.
If the problem still exists, contact Lenze.

45581
(B20D)

Error when reading from the target system.

Reset the target system.
Then try again.

45582
(B20E)

Error when writing to the target system.

Reset the target system.
Then try again.

15.5.4

System-oriented communication error

Note!

System-oriented communication error at the CAN bus

A system-oriented error occurred at the CAN bus.
Please check

the network hardware
(connections, cables, terminating resistors).

the system bus adapters used.

the configuration settings

(no double assignment of node addresses, identical baud rates).

Restart the PC.