Drive PLC Developer Studio

Program example

3-9

l

DDS EN 2.3

The traffic light example requires a step for every traffic light phase.

31.Select the transition Trans0 (click the horizontal line to the left of Trans0 ) to frame it with a

dotted line.

32.Select Insert

Step transition (after) to insert a step transition after Trans0.

33.Repeat the above step seven times to create the following sequential function chart:

– To delete a step or transition, select the step and the associated transition, otherwise they

cannot be deleted.

– First click the step, press <Shift>, then click the transition.

Clicking the name of a transition or step directly will invert the text for editing.

34.Change the name of the first transition after Init to TRUE.

35.Change the names of all subsequent transitions to ” WAIT1.OK” .

The first transition switches all the time, all other transitions when WAIT1 in OK becomes
TRUE

, i.e. when the specified time has expired.

36.Change the names of the steps as described below (from top to bottom):

– Init (remains unchanged)
– CHANGE1
– GREEN1
– CHANGE2
– RED1
– CHANGE3
– GREEN2
– CHANGE4
– RED2

” CHANGEx” stands for a amber phase each time, “ GREEN1” means that traffic light 1 will be
green and “ GREEN2” applies for traffic light 2, “ RED1” means that traffic light 1 will be red
and “ RED2” applies for traffic light 2.