Drive PLC Developer Studio

Resources

8-5

l

DDS EN 2.3

Adding code with initial value:

1. In the dialog box

Code initialization value, click New to add a code with initial value.

2. Use the dialog box

Initialize value, input field Code to enter the number of the code (without

preceding ” C” ) for which an initial value is to be defined.

3. Use input field Initialize value to enter a value for code initialization.

4. If the code has subcodes, use input field Subcode to enter the associated subcode.

5. Optionally, input field Remark can be used to enter a comment to be displayed in dialog box

Code initialization values.

6. Confirm with OK to accept the input, or select Cancel to end the process and close the

dialog box.

Changing the initial value of a code:

1. In the list box, use the mouse pointer symbol

to click on the line with the code to be

changed.

2. Use dialog box

Initialize value to change the values as required, and confirm with OK.

Deleting code with initial value:

1. In the list box, use the mouse pointer symbol

to click on the line with the code to be

deleted.

2. Use dialog box

Initialize value, button Delete to delete the selected code.

Example:

A project using a 9300 Servo PLC is to always use the same motor type. To avoid repeated
reconfiguration, the motor type can be ” hardwired” in the project with the help of code initialization
values.

0086 = Motor type selection code

Initialization value 108 = motor type MDSKSXX036-13, f

N

: 200 Hz