Commands in the “Project” menu

7.8.4.1

Add action

Icon:

-

Menu:

Project WAdd action

Keyboard:

-

Use this command to generate an action for the selected SFC organization unit in the

Object

Organizer, that can be used for the IEC steps of this organization unit.

Select the action name and the language to be used to implement the action from the dialog
box displayed after command selection.

The new action will be added under its SFC organization unit in the

Object Organizer,. and a plus sign

will appear in front of the SFC organization unit.

Click the plus sign to display all action objects. A minus sign will appear in front of the
organization unit.

Click the minus sign to hide the actions again and to return the plus sign.

Tip!

The shortcut menu commandsExpand node and Minimize node can also be used to display or
hide the objects.

Double-clicking the action or pressing <Enter> loads the action into the editor.

7.8.5

SFC flags

So called SFC flags will be set if a step in SFC is active longer than specified in its attributes.

The user can define more variables to control the sequential function chart.

Before SFC flags can be used they must be declared. The declaration may be global or local, as
output or input variable.

SFCEnableLimit

Variable is of type BOOL.

If this variable is TRUE , step timeouts will be registered inSFCError. Otherwise, timeouts will
be ignored.

SFCInit

Variable of type BOOL.

If this variable is TRUE , the SFC will be reset to the init step and the other SFC flags will be
reset, too. The init step remains active but will not be executed as long as the variable is
TRUE

. Only if SFCInit is reset to FALSE will the organization unit be processed normally

again.

SFCReset

This BOOL -type variable behaves similarly to SFCInit. Here, however, init step processing is
continued after initialization. This aspect can be used to reset the SFCReset flag in the init step
immediately to FALSE.

Tip!

SFCInit

and SFCReset cannot be used simultaneously in one organization unit. SFCInit will

always have priority.