Drive plc developer studio – Lenze DDS v2.3 User Manual

Page 162

Advertising
background image

Drive PLC Developer Studio

Editors

7-40

l

DDS EN 2.3

7.6.4.5

Set/ Reset

Icon:

-

Menu:

Extras WSet/Reset

Keyboard:

-

Use this command to define coils as Set or Reset coils.

A Set coil is identified with an ” S” in the coil symbol.

If the network result is TRUE , the Boolean variable, as a consequence of the Set coil, will be set
to TRUE . Otherwise, the variable will remain as it is.

If the network result is TRUE , the Boolean variable, as a consequence of the Set coil, will be set
to TRUE . Otherwise, the variable will remain as it is.

A Reset coil never overwrites the value FALSE in the associated Boolean variable.

A Reset coil is identified with an ” R” in the coil symbol.

If the network result is TRUE , the Boolean variable, as a consequence of the Reset coil, will be set
to FALSE. . Otherwise, the variable will remain as it is.

If the command is executed more than once, the coil toggles between Set, Reset and normal coil.

7.6.4.6

Open instance

This command corresponds to the command Project

WOpen instance.

7.6.4.7

Options

Icon:

-

Menu:

Extras WOptions

Keyboard:

-

Use this command to open the dialog box

Function block and ladder diagram options .

Completing the input fields as illustrated will update the associated contact with the following
comment field.

Use the input fields Minimum comment size and Maximum comment size to enter a comment
on the current contact or the current coil.

If check box Comments per contact is active, the input fields Lines for variable comment can
be used to input a variable-specific comment, and Lines for variable text to specify a variable
name.

If check box Networks with line breaks is active, the network will break depending on the window
size.

Show/Hide Bookmarks

Advertising