Drive PLC Developer Studio

Resources

8-12

l

DDS EN 2.3

8.4.3.3

Adding codes

Select Insert

WAdd new object to add a new code.

Note!

It is not permissible to create codes on system variables.

No codes can be created for REAL variables.

Open the dialog box

Enter the new object to select the variable to be linked to the code.

Selection of the variable and confirmation with OK will open the dialog box

Instance

Parameter Manager where the settings for a code can be made.

The Instance Parameter Manager supports the following data types.

BOOL

BYTE

SINT

USINT

INT

UINT

DINT

UDINT

WORD

DWORD

Note!

Copy and insert actions on objects will completely replace the contents.

8.4.3.4

Dialog box Instance Parameter Manager

Open the dialog box

Instance Parameter Manager to edit the settings for an existing or specify the

settings for a new code.

Note!

System variables must not be linked with write/read codes.

Code/ index

The code range from C3000 to C7999 is available. Code numbers are entered without the
leading ’C’.

Clicking the button First instance inserts the known parameter code in the input field Code.
The input fields Code max./Code min. and Int. max./Int. min. are greyed out.

Selecting an existing code will return an error message on clicking OK.

Show/Hide Bookmarks