1 declaration part, 2 input variables, 3 output variables – Lenze DDS v2.3 User Manual

Page 133: Declaration part, Input variables, Output variables, Drive plc developer studio

Advertising
background image

Drive PLC Developer Studio

Editors

7-11

l

DDS EN 2.3

7.2.1

Declaration part

The declaration part of an organization unit declares all variables locally.

These may be

input variables,

output variables,

input / output variables,

local variables,

retentive variables,

constants

and retentive constants.

The declaration syntax is based on the IEC 61131-3 standard.

7.2.1.1

Declaration keywords

Icon:

-

Menu:

InsertWDeclaration keywords

Keyboard:

-

Use this command to open a list of all keywords available for use in the declaration part of an
organization unit.

The keyword will be inserted at the current cursor position once it has been selected and
confirmed.

The list will also be displayed when calling the Help Manager and selecting the category
Declarations.

7.2.2

Input variables

Between the keywords VAR_INPUT and END_VAR, all variables are declared that are used as input
variables for an organization unit.

The values of these variables can be transferred from the calling unit.

Example:

VAR_INPUT

in1:INT; (* 1. input variable *)

END_VAR

Input variables can be used to transfer data from the calling to the called organization unit.

7.2.3

Output variables

Between the keywords VAR_OUTPUT and END_VAR, all variables are declared that are used as
output variables for an organization unit.

The values of these variables are returned to the calling organization unit for further use.

Example:

VAR_OUTPUT

out1:INT; (* 1. output variable *)

END_VAR