Drive PLC Developer Studio

Resources

8-22

l

DDS EN 2.3

Tip!

Note that data inconsistencies may occur if analog input 1 is used several times within the cyclical
task.

As the process image is updated every 3 ms within the 40 ms of cyclical task processing,
there may be different input values for analog input 1.

Event-controlled task (EVENT)

If system organization units are used in one event-controlled task only, their process image
will be generated in the event-controlled task.

If the same system organization units (that are not also used in a time-controlled task) are
used in two event-controlled tasks, their process image will be generated in the cyclical task.

Tip!

For further information about tasks, refer chapter 8.8, “ Task configuration” .

(

^ 8-29)

Interrupt-controlled task

If system organization units are used in one event-controlled task only, their process image
will be generated in the event-controlled task.

If the same system organization units (that are not also used in a time-controlled task) are
used in an event-controlled and an interrupt-controlled task, their process image will be
created in the cyclical task.