Rockwell Automation Publication 1756-UM514C-EN-P - June 2014

129

Using the Studio 5000 Environment in Remote I /O and Block Transfer Applications

Chapter 10

Configure the Remote I/O Modules

Configure the newly added remote I/O modules.

Naming Screen (first
screen):

Parameter:

Definition:

Name

Module name. This field is required.

Description

Optional description of the module.

Group

Determines what group on the module provides the first word of I/O data.
This selection is affected by the parent module’s configuration. For example,
if the parent module’s size = 1/2 rack (4 I/O groups), this module’s
configuration offers the option of starting with group 0, 1, 2 or 3.

Slot

Location of the remote I/O module.