Messaging Between PLC-5 or SLC 5/04 Controllers and ControlLogix Controllers

DH+ Messaging: PLC-5
Controllers to One
ControlLogix Controller with
One ControlLogix Chassis

This application sends a DH+ message from PLC-5/60 controller A through a
1756-DHRIO or 1756-DHRIOXT module to ControlLogix controller B.
Local DH+ messaging can be used to send the message.

The following figure illustrates the steps you must use in this application.

IMPORTANT

Local DH+ messaging can send only DH+ messages to one ControlLogix
controller per DH+ channel. See the application on page

83

if you want to

send DH+ messages to multiple ControlLogix controllers in the chassis.

1756-DHRIO
Slot Number: 3

PLC-5/60 Controller A
Node Number: 005

DH+ Link
Link ID 1

41283

Channel A
Node Number: 010

ControlLogix Controller
Slot number: 1

IMPORTANT

For this application, the 1756-DHRIO and 1756-DHRIOXT modules need
only a controller slot programmed if the ControlLogix controller is not in the
default slot (0) of the ControlLogix chassis.