PCCC Commands Supported by the Data Highway Plus Module

ID Host and Status

This command lets you check the location and status of the controlling
intelligent device, such as a PLC-5, that is connected to the DHRIO network.

CMD = 06h, FNC = 03

The definition of the data returned is shown in the following table.

Byte

Description

0

PLC Mode = 00

1

Interface Type = 0xEE

2

Interface Type Extension = 0x3D

3

Processor Type Extension = 0x76

4 - 5

Reserved

6

Pointer to Diagnostic Counters (low byte) = 00

7

Pointer to Diagnostic Counters (high byte) = 00

8

Major and Minor Revision

Bits 0 - 3

1 = Minor Revision 1

2 = Minor Revision 2

and so forth

Bits 4 - 7

1 = Major Revision 1

2 = Major Revision 2

and so forth

9

Options - Port A

Bits 0 - 1

Port A Type, where

00 = illegal

01 = remote I/O

10 = DH+

11 = illegal

Bits 2 - 3

Unused

Bits 4 - 5

Port A Baud Rate, where

00 = 57.6 Kb

01 = 115 Kb

10 = 230 Kb

11 = illegal

Bits 6 - 7

Unused