Rockwell Automation 2755 AtomScan Bar Code Reader User Manual
Page 11

1–3
Introduction to AtomScan
+
Bar Code Readers
Publication 2755-6.9
3.
Install the reader.
Reference
Mount the reader (Catalog Nos. 2755-LS7-SA, 2755-LS7-SB, 2755-LS7-RA, 2755-LS7-RB,
2755-LS7-SBV, or 2755-LS7-RBV) to the mounting plate (Catalog No. 2755-LS7-N) or directly to your
mounting surface. [The maximum distance from the reader to another device is 3 ft. (0.91 m)]. Use
# 6 screws with maximum penetration of 0.15 in. (3.81 mm). If you are not using the mounting plate,
go to step #4.
Chapter 4
(Installing Your
Hardware)
Reader
Mounting Plate
Mount the plate to your mounting surface. You can mount the plate to the top, bottom, or side of your
mounting surface. Use # 6 screws.
Make sure placement of the mounting plate will allow you to connect the reader to the interface box
(Catalog Nos. 2755-LS7-IB1 or 2755-LS7-IB2) or other network device. The maximum distance from
the interface box to the reader is 3 ft. (0.91 m). Skip steps #4 and #5 if you are not using an interface
box.
Reader
Mounting Surface