Configuring Your Reader
Publication 2755-6.9
•
I 2 of 5. Code length #1 can be zero or any even number from 2
to 64. The default is 10. Code length #2 can be zero or any even
number from 2 to 64. The default is 6.
Command
Parameter
Format
Example
Status
0 = Disabled
1 = Enabled
Check Digit Status
<Krstatus,check digit,check
To set Fixed Code Length #1 to 8 and #2
0 = Disabled
Kr
<Krstatus,check digit,check
digit output,length 1,
To set Fixed Code Length #1 to 8 and #2
to 4, press
[<Kr1,,,8,4>]
or
1 = Enabled
Kr
digit output,length 1,
length 2>
to 4, press
[<Kr1,,,8,4>]
or
[<Kr1,0,0,8,4>]
.
Check Digit Output Status
0 = Disabled
1 = Enabled
•
UPC/EAN. The Separator character can be any ASCII character
except NUL. The default is , .
Command
Parameter
Format
Example
UPC Status
0 = Disabled
1 = Enabled
EAN Status (UPC must be enabled)
0 = Disabled
1 = Enabled
<KsUPCstatus,EAN
status,supplementals
To change Supplementals to Required,
Supplementals Status
Ks
status,supplementals
status,separator
and change Separator Character to a
0 = Disabled
Ks
status,separator
status,separator cha.>
dash (–), press
[<Ks1,1,2,1,–>]
1 = Enabled
[<Ks1,1,2,1,–>]
.
2 = Required
Separator Status
0 = Disabled
1 = Enabled
•
Code 128. You can use any number between 1 and 64 for the
Code Length. The default is 10.
Command
Parameter
Format
Example
Status
0 = Disabled
1 = Enabled
To enable Code 128, enable Fixed Code
Fixed Code Length Status
Kt
<Ktstatus,fixed
Length, and set Code Length to 9, press
[<Kt1 1 9>]
0 = Disabled
length,length>
[<Kt1,1,9>]
.
1 = Enabled
•
Code Types Status Request. Allows you to return the status of
each command in the group.
Parameter
Format
KW
<KW?>