Scanner Output Commands

Relay–1. The pulse width occurs in 10 millisecond increments.
You can use any number between 2 and 255. The default is 5.

Command

Parameter

Format

Example

Output On

0 = Mismatch or No Read

1 = Match or Good Read

2 = Mismatch

<Kvoutput on,polarity,pulse

To set Relay 1 to Mismatch and change

3 = No Read

Kv

<Kvoutput on,polarity,pulse
width>

Pulse Width to 40 ms, press

[<Kv2 0 4>]

[<Kv2 4>]

Polarity

[<Kv2,0,4>]

or

[<Kv2,4>]

.

0 = Negative

1 = Positive

Relay–2. The pulse width occurs in 10 millisecond increments.
You can use any number between 2 and 255. The default is 5.

Command

Parameter

Format

Example

Output On

0 = Mismatch or No Read

1 = Match or Good Read

2 = Mismatch

<Kwoutput on,polarity,pulse

To set Relay 2 to Mismatch and change

3 = No Read

Kw

<Kwoutput on,polarity,pulse
width>

Pulse Width to 40 ms, press

[<Kw2 0 4>]

[<Kw2 4>]

Polarity

[<Kw2,0,4>]

or

[<Kw2,4>]

.

0 = Negative

1 = Positive

Bar Code Output

Command

Parameter

Format

Example

Status

0 = Disabled

1 = Match

2 = Mismatch

To set When to Output to End of Read

3 = Good Read

KI

<Klstatus,when to output>

To set When to Output to End of Read
Cycle, press

[<KI3,1>]

.

When to Output

[

,

]

0 = As soon as Possible

1 = End of Read Cycle

No Read Message. You can use any ASCII string up to 7
characters in length. The default is No Read.

Command

Parameter

Format

Example

Status

To enable No Read Message and send

0 = Disabled

Kk

<Kkstatus,output>

To enable No Read Message and send
the message FAIL, press

1 = Enabled

Kk

<Kkstatus,output>

the message FAIL, press

[<Kk1,FAIL>]

.