Application Examples

E–5

Publication 2755-6.9

Flexible Interface Module Setup

You need to configure the flexible interface module. Follow the
steps below or refer to the Flexible Interface Module User Manual
(Publication No. 2760-ND001) or the SFC1 or SFC2 Protocol
Cartridge User Manuals
(Publication Nos. 2760-ND002 or
2760-822).

1. Select 90B to reset the configuration to factory defaults.

2. Configure screens 3, 21, and 11 (in this order) as shown starting

below.

2760–RB SERIES A REVISION J
COPYRIGHT 1989 ALLEN–BRADLEY COMPANY, INC.
––––––––––––––––––––––––––––––––––––––––––––––––––––

1X – CONFIGURATION PARAMETERS 2X – IDENTIFICATION NUMBERS
3 – DEVICE PORT PROTOCOL NAMES 4DM – MATCH CODE ENTRIES
5I – DISCRETE BYTE INPUT ENTRIES 6 – THE DATA MATRIX ENTRIES
7 – THE PASS THROUGH ENTRIES 8 – NON–VOLATILE SCRATCH PAD AREA
9XF – RB MODULE FUNCTIONS AX – HARDWARE DIAGNOSTICS
BX – SOFTWARE DIAGNOSTICS C – EXIT CONFIGURATION MODE

WHERE X (0 TO 7) AND D (1 TO 3) ARE PORT NUMBERS WHICH ARE DEFINED BELOW :

0 – RB CMMND PRCSS 2 – SERIAL PORT 2 4 – CONFIG PORT 6 – I/O RACK SLT 1
1 – SERIAL PORT 1 3 – SERIAL PORT 3 5 – I/O RACK SLT 0 7 – RESERVED

WHERE F (A TO E) ARE FUNCTIONS THAT RB CAN PERFORM WHICH ARE DEFINED BELOW :

A – RESET B – SET DEFAULTS C – FLUSH D – INITIALIZE E – CLEAR DIAGS

WHERE M (A TO T) AND I (A TO H) ARE ENTRY NUMBERS FOR THE SELECTION MADE ABOVE.

ENTER A MAIN MENU SELECTION:

ENTER A MAIN MENU SELECTION: 3

PORT 1 = COPYRIGHT 1989 ALLEN–BRADLEY COMPANY, INC.
2760–SFC1 DT , SERIES A , REVISION B (YES/NO) = YES.

PORT 2 = COPYRIGHT 1989 ALLEN–BRADLEY COMPANY, INC.
2760–SFC1 DT , SERIES A , REVISION B (YES/NO) = YES.

PORT 3 = COPYRIGHT 1989 ALLEN–BRADLEY COMPANY, INC.
2760–SFC1 DT , SERIES A , REVISION B (YES/NO) = YES.

EDIT THIS SELECTION (YES/NO) ?